ATX FE series explosion proof emergency lights are suitable for use in Atex rated hazardous area zone 1, zone 2, zone 21 & zone 22, ingress protection rated IP66/67, for wall or ceiling mounting, has an electronic multi-tap ballast, high impact resistance housing, hinged parabolic reflector and vibration resistant lamp holders suitable for 2 x 58W G13 fluorescent bi-pin lamp.

More details

91383

10 Other products in the same category

ATX FE series hazardous area emergency lights fittings are explosion proof and suitable for wall or ceiling surface mount in zone 1, zone 2, zone & zone  22, hazardous areas. 3 hour battery, LED indication, electronic ballast, suitable for 2 x 58w G13 fluorescent bi-pin lamp and central locking via allen key socket spanner. explosion proof equipment protection Gas: Ex II 2 GD, rated voltage AC/DC 110V .... 254V 50/60 Hz, ingress protection: IP66/67, Enclosure material: glass fibre reinforced polyester resin, cover material: polycarbonate, gasket material: elastomer, ambient temperature: -40ºC .....+55ºC, Terminals 6 terminals -6 sq.mm (solid), 4 sq.mm (flexible), Cable Entries: 3 x M25

Applications:
• Can be installed in hazardous areas designated as Zone 1, 2, 21 and 22.
• For use in locations where a high degree of corrosion resistance is required.
• For indoor/outdoor use where protection against dirt, water and moisture is necessary.
• Typical applications include oil refineries, petrochemical facilities, pulp and paper mills, food processing plants, warehouses, underground tunnels and general manufacturing facilities.

 2 x 58W T6 lamp are not supplied

ATX FE series ATEX approval details
Area classificationHazardous area, Zone 1, Zone 2 (Gas), Zone 21, Zone 22 (Dust), Ordinary
ATEX certificationIECEx LCI 04.0017
ATEX approvalsEx II 2 GD
ATEX markingEx edms IIC T4
 Ex tD A21 IP66/67 T100°C 
  
ATX FE series technical details
Enclosure materialCorrosion resistant glass fibre reinforced polyester resin (20 Joules - IK10)
Cover materialPolycarbonate
Gasket materialElastomer
Ingress protection:IP66/67
Cable entries3 x M25
Operating temperature-40°C to +55°C ambient and wind profile for harsh offshore and onshore environments
Ballast1 x electronic multi-tap dual channel with monthly self test
Battery duration3 hour
Battery maintenanceSelf test, LED indication, Exe with plug-in connector
Supply voltage:AC 110 (-10%) …254 (+10%) V, 50/60 Hz
 DC 110…254 V, 50/60 Hz
Lamp holder2 x 58W  T8 (G13) 
Lamp disconnectPositive safety switch disconnects power to lamps and ballast
Terminals2 x 5 terminals, 6mm² solid core, 4m² flexible core
Weight7.9 kg