8KTV2-CT-T2 Raychem trace heating cable Maximize

8KTV2-CT-T2 Raychem trace heating cable

Raychem 8KTV2-CT-T2 self regulating electric trace heating cable, mostly used mainly for temperature maintenance of pipes, tanks or vessels subjected to steam cleaning. 25 w/m output, 230V, fluoropolymer outer jacket approved for use in hazardous areas Zone 1, Zone 2, Zone 21(Gas) & Zone 22 (Dust). Capable of continuous exposure temperatures up to +150°C, intermittent temperatures up to 250°C

More details

Add to cart

3 Other products in the same category

The 8KTV2-CT-T2 Raychem self-regulating parallel circuit trace heating cable is mostly used for temperature maintenance of pipe, tanks or vessels which are subjected to steam cleaning. It may also be used in a variety of industrial applications for process temperature maintenance up to 150°C. It may also be used for frost protection of large pipes and applications requiring high temperature exposure capability. When used in hazardous areas the unconditional T2 temperature classification simplifies designs and 8KTV2-CT-T2 can be overlapped at valves or flanges with no risk of overheating. The cut to length capability of KTV family heat tracing cables simplifies electric heat tracing designs for complex piping systems and installation times are reduced due to state-of-the-art connection kits. The self-regulating principle of KTV heating cables will ensure that the system runs efficiently, saving energy and thereby operational costs.

Technical Details:
Area classificationHazardous area, Zone 1, Zone 2 (Gas), Zone 21, Zone 22 (Dust)
Traced surfaced typeCarbon steel, stainless steel, plastic, painted or unpainted
Chemical resistance:Organic corrosive solutions
Supply voltage230 Vac
  
ATEX approvalsPTB 09 ATEX 1117 X & Baseefa 06ATEX0186X
ATEX markings Ex II 2G Ex e II 226°C (T2) & Ex II 2D Ex tD A21 IP66 T226°C
 IECEx PTB 09.0058X & IECEx BAS 06.0046X
 Ex II 2G Ex II 226°C (T2) & Ex II 2D tD A21 IP66 T226°C
 DNV Certificate No E-8934 for use on ships and mobile offshore units
Maintain temperature150°C (maximum)
Intermittent temperature250°C (20 bar saturated steam, maximum cumulative exposure 1000 hours)
Temperature classificationT2 in accordance with European Standard EN 60079-30-1 5.1.13
Installation temperature-60°C minimum
Bend radius26mm at  20°C
 51mm at -60°c
Physical properties:
Thickness7.6mm
Width13.3mm
Weight250 g/metre
Conductors2 x 2.3mm² nickel plated copper
Outer sheathFluoropolymer
Power Output

25 watt per metre

Maximum circuit length based on type ‘C’ circuit breakers according to EN 60898:
Electric protection sizeStart-up temperatureMaximum cable length
16A-20°C95 m
  10°C105 m
25A-20°C150 m
  10°C165 m
32A & 40A-20°C180 m
  10°C180 m