Product details
nVent RAYCHEM C-150-E connection kit is for terminating all nVent RAYCHEM BTV, QTVR,XTV, XTVR and KTV self-regulating heating cables to a flexible power cable, whilst maintaining electrical insulation of the cable conductors and core. The C-150-E can be used in applications with temperature ranging from -50°C to +215°C and, is approved for use in hazardous areas
Features & Benefits
- Easy to use and fast to install
- Cold applied: no heat gun, no hot work permit needed
- Versatile: approved for all nVent RAYCHEM self-regulating heating cables
- Simplified design in hazardous area, part of system approval
- Reliable long life: maintenance free, 10 year product warranty available
- TECHNICAL DETAILS
SPECIFICATIONS Approved nVent RAYCHEM self-regulating heating cables: BTV,QTVR,XTV, XTVR and KTV Power cable capability type: nVent RAYCHEM power cable C-150-PC, H07RN-F or silicone insulated
diameter: ⌀ 7.8 mm to 12.5 mm
conductors: 3 x 1.5 mm2 to 2.5mm2Type cold applied Maximum operating voltage 277 VAC Maximum current depending on the power cable used and maximum current Max. exposure temperature power ON: +150°C:
power OFF: +200°CMin. ambient temperature -55°C Enclosure material Engineering polymers, colour BLACK Sealing grommets silicone rubber Screws and compression springs stainless steel Temperature classification IP 66 Weight (kg) 0.4 C-150-E connection kit contentsSplice enclosure assembly 1 Core sealer 1 spacer/screw terminals 1 Power cable sealing grommet assembly 1 Power cable strain relief plate 1 I.D. label 1 * IMPORTANT* The above numbers are for circuit length estimation only. For more detailed information please request nVent RAYCHEM TraceCalc software design. nVent requires the use of a 30 mA residual current device to provide maximum safety and protection from fire. Where design results in higher leakage current, the preferred trip level for adjustable devices is 30 mA above any inherent capacitive leakage characteristic of the heater as specified by the trace heater supplier or alternatively, the next common available trip level for non adjustable devices, with a maximum of 300 mA. All safety aspects need to be proven - APPROVALS
APPROVALS ATEX: DEKRA 20ATEX0011U
Ex II 2 G Ex eb IIC GB
Ex II 2 D Ex tb IIIC DbIECEX: DEK 20.0005U
Ex eb IIC Gb
Ex tb IIIC DbDNV TAE00000TU and TAE 00000TV
When used with BTV, QTV heating systems: DNV certficate TAE00000TU
When used with KTV, XTV heating systems: DNV certificate TAE00000TVEAC Ex RU C-BE.MЮ62.B.00054/18
1Ex e IIC Gb U
Ex tb IIIC Db U
Ta -55°C...+150°C Power ON IP66
Ta -55°C...+200°C Power OFF
ООО "ТexИмпорт"CCC
Ex e IIC Gb
Ex tD A21 IP66 - DOWNLOAD DOCUMENTS