RAYCHEM C-150-E power connection kit, cold applied, low profile - nVent

nVent Raychem C-150-E power connection kit for self-regulating heating cables, hazardous area

RAYCHEM C-150-E power connection kit, cold applied, low profile - nVent


$0.00
$121.78
/ ea
Earn0
reward points

Lead time: 3 to 5 days


Product details

nVent RAYCHEM C-150-E connection kit is for terminating all nVent RAYCHEM BTV, QTVR,XTV, XTVR and KTV self-regulating heating cables to a flexible power cable, whilst maintaining electrical insulation of the cable conductors and core. The C-150-E can be used in applications with temperature ranging from -50°C to +215°C and, is approved for use in hazardous areas 

Features & Benefits

  • Easy to use and fast to install
  • Cold applied: no heat gun, no hot work permit needed
  • Versatile: approved for all nVent RAYCHEM self-regulating heating cables
  • Simplified design in hazardous area, part of system approval
  • Reliable long life: maintenance free, 10 year product warranty available
  • TECHNICAL DETAILS
    SPECIFICATIONS
    ApprovednVent RAYCHEM self-regulating heating cables: BTV,QTVR,XTV, XTVR and KTV
    Power cable capabilitytype: nVent RAYCHEM power cable C-150-PC, H07RN-F or silicone insulated
    diameter: ⌀ 7.8 mm to 12.5 mm
    conductors: 3 x 1.5 mm2 to 2.5mm2
    Typecold applied
    Maximum operating voltage277 VAC
    Maximum currentdepending on the power cable used and maximum current
    Max. exposure temperaturepower ON: +150°C:
    power OFF: +200°C
    Min. ambient temperature-55°C
    Enclosure materialEngineering polymers, colour BLACK
    Sealing grommetssilicone rubber
    Screws and compression springsstainless steel
    Temperature classificationIP 66
    Weight (kg)0.4


    C-150-E connection kit contents
    Splice enclosure assembly 1
    Core sealer1
    spacer/screw terminals1
    Power cable sealing grommet assembly1
    Power cable strain relief plate1
    I.D. label1


    * IMPORTANT* The above numbers are for circuit length estimation only. For more detailed information please request nVent RAYCHEM TraceCalc software design. nVent requires the use of a 30 mA residual current device to provide maximum safety and protection from fire. Where design results in higher leakage current, the preferred trip level for adjustable devices is 30 mA above any inherent capacitive leakage characteristic of the heater as specified by the trace heater supplier or alternatively, the next common available trip level for non adjustable devices, with a maximum of 300 mA. All safety aspects need to be proven
  • APPROVALS
    APPROVALS
    ATEX: DEKRA 20ATEX0011U
    Ex II 2 G Ex eb IIC GB
    Ex II 2 D Ex tb IIIC Db

    IECEX: DEK 20.0005U
    Ex eb IIC Gb
    Ex tb IIIC Db
    DNV TAE00000TU and TAE 00000TV
    When used with BTV, QTV heating systems: DNV certficate TAE00000TU
    When used with KTV, XTV heating systems: DNV certificate TAE00000TV

    EAC Ex RU C-BE.MЮ62.B.00054/18
    1Ex e IIC Gb U
    Ex tb IIIC Db U
    Ta -55°C...+150°C Power ON IP66
    Ta -55°C...+200°C Power OFF
    ООО "ТexИмпорт"

    CCC
    Ex e IIC Gb
    Ex tD A21 IP66


  • DOWNLOAD DOCUMENTS