RAYCHEM E-100 end seal for use in hazardous and non hazardous areas - nVent

NVent Raychem E-100-E end seal termination kit for use in hazardous areas and non hazardous locations

RAYCHEM E-100 end seal for use in hazardous and non hazardous areas - nVent


$0.00
$88.67
/ ea
Earn0
reward points


Lead time: 3 to 5 days


Product details

nVent RAYCHEM E-100 end seal kits with integral pipe mount stand. Electrostatic charge resistant glass filled engineered polymer enclosure, forms part of the integrated components system. The E-100 end seal kits terminate one heating cables and are approved for use in hazardous areas with nVent RAYCHEM BTV, HTV, KTV, QTVR, XTV and XTVR self-regulating heating cables, and nVent RAYCHEM VPL power limiting heating cables. The E-100 is available in 2 variants:

  • E-100-E end seal without LED indicator light
  • E-100-L-E end seal with LED indicator light

Features & Benefits

  • Rugged: integral pipe mount stand protects heating cables
  • Simple to design: up to 480 VAC, 40 A
  • Easy to install: re-entrable seal, no hot work permit required
  • Reliable long life: maintenance free, 10 year product warranty available
  • TECHNICAL DETAILS
    SPECIFICATIONS
    ApprovednVent RAYCHEM heating cables: BTV, HTV, KTV, QTRV, XTV and XTVR self-regulating; VPL power limiting
    Rated voltage480 VAC
    Max. current rating 40 A
    LED version onlyGreen LED
    voltage 110-277 VAC
    power consumption < 2 W 
    Temperature rangeE-100-E  -55°C to +56°C
    E-100-L-E -40°C to +40°C
    Min. installation temperatureE-100-E  -55°C
    E-100-L-E  -40C
    Enclosure materialelectrostatic charge resistant glass filled polymer: Colour BLACK
    Impact resistanceEN 60079-30-1, ≥7 joules
    UV stabilityno degradation after > 1000 h
    Temperature classificationIP 66
    E-100 end seal kit contents
    ContentE-100-EE-100-L-E
    end seal enclosure 11
    LED light indicatorN/A1
    cable tie11
    polywater sachet11
    insulated parallel crimpsN/A2
    core sealerN/A1
    * IMPORTANT* The above numbers are for circuit length estimation only. For more detailed information please request nVent RAYCHEM TraceCalc software design. nVent requires the use of a 30 mA residual current device to provide maximum safety and protection from fire. Where design results in higher leakage current, the preferred trip level for adjustable devices is 30 mA above any inherent capacitive leakage characteristic of the heater as specified by the trace heater supplier or alternatively, the next common available trip level for non adjustable devices, with a maximum of 300 mA. All safety aspects need to be proven


  • APPROVALS
    APPROVALS
    E-100-EE-100-L-E
    ATEX: PTB 09.1060U
    Ex II 2 G Ex eb mb IIC Gb
    Ex II 2 D Ex tb mb IIIC Db
    IP66
    Ta -55°C to +56°C
    ATEX: Sira 14ATEX3015X
    II 2 G Ex eb mb IIC T* Gb
    II 2 D Ex tb IIIC T**°C Db
    IP66
    Ta -40°C to +40°C
    IECEX: IEC PTB 09.0038U
    Ex eb mb IIC Gb
    Ex tb mb IIIC Db

    IECEX: PTB 21.0007X, PTB 21ATEX1003X
    Ex eb mb IIC Gb
    Ex tb mb IIiC Db
    DNV: TAE0000TU and TAE00000TV
    The E-100 approved by DNV for use on ships and mobile offshore units

    EAC Ex: RU C-BE.MЮ62.B00054/18 (1)
    Ex e IIC Gb U or Ex tb mb IIIC Db U
    Ex e mb IIC Gb U
    Ex tb mb IIIC Db U
    Ta -55°C...+56°C  IP66
    ООО "ТexИмпорт"
    EAC Ex: RU C-BE.MЮ62.B00054/18(1)
    Ex e IIC Gb U Ex tb IIIC Db U
    Ex e mb IiC Gb U
    Ex tb mb IIIC Db U
    Ta -40°C ...+40°C IP66
    ООО "ТexИмпорт"
    CCC (1)
    Ex e IIC Gb
    Ex tD A21 IP66

    CCC (1)
    Ex e mb IIC T* Gb
    Ex tD A21 mbD21 T*°C IP66
    (1) HTV approval pending
  • DIMENSIONS



    DIMENSIONS AND WEIGHT

    E-100-EE-100-L-E
    Stand height (mm)
    119
    119
    Enclosure width (mm)
    46
    66
    Overall height (mm)
    171
    197
    Weight (kg)
    0.22
    0.63
  • DOWNLOAD DOCUMENTS