RAYCHEM Elexant 650c-Modbus controller for roof and gutter de-icing, surface snow melting and ramp heating heat trace cable systems - nVent

New
nVent RAYCHEM Elexant 650C-Modbus control unit for roof and gutter de-icing, surface snow melting and ramp heating cable systems

RAYCHEM Elexant 650c-Modbus controller for roof and gutter de-icing, surface snow melting and ramp heating heat trace cable systems - nVent


$0.00
$733.52
/ ea
Earn0
reward points

Lead time: 5 to 7 days


Product details

nVent RAYCHEM Elexant 650c-Modbus electronic controller provides control of nVent RAYCHEM cables for roof and gutter de-icing, surface snow melting and ramp heating heat trace cable systems. The Elexant 650c Modbus connectivity allows for remote monitoring, configuration and ease of integration in a Building Management System (BMS)

Elexant 650C-Modbus: Features & Benefits

  • Touch screen: intuitive set-up, 4.3" colour
  • Flexible control: moisture and temperature control
  • Dual zone: control 2 independent heating areas
  • Ice rain feature: pre-heating the surface to prevent the issue from freezing rain
  • Offsite configuration: can be set up prior to installation
  • USB port: offsite configuration, firmware upgrades
  • Alarm relay: signals power, sensor or communication status
  • Switching: SPDT, 2 x 4 A / 230 V a.c.
  • RS485 port: Modbus communication to BMS system
  • Pre-programming: using RAYCHEM-PB-Powerbank in case no power supply on site during installation (sold separately)


  • TECHNICAL DETAILS
    SPECIFICATIONS
     
    ApplicationRoof and gutter de-icing, ramp and surface snow melting

    nVent RAYCHEM heating cables ICESTOP-GM2X, ICESTOP-GM2XT and FroStop Black, EM2-CM-MAT, EM2-MI, EM2-XR, EM4-CW
    Area of UseOrdinary area, outdoors
    Exposure temperature range0°C to +40°C
    Electrical
    Supply voltage230 Vac -15/+10% 50/60 Hz
    Power consumptionmax. 25 VA
    TerminalsPower supply: 3 x 1.5 mm²
    Heating circuit output: 2 x 2 x 1.5 mm²
    Alarm: 3 x 1.5 mm²
    Sensor: 2 x 2 x 1.5 mm²

    Modbus: 3 x 1.5 mm² 
    Alarm relaySingle pole double throw (SPDT); volt free 2 A / 250 V a.c.
    Time clockAutomatic summer/winter and leap year correction
    Clock back up /accuracy3 years, ± 10 minutes per year
    KeylockPassword protection for parameter settings
    USB portPre-installation set-up in power off mode; firmware upgrade
    Display and programming
    Screen typeTouch screen, size 4.3"
    LED indication (GREEN)

    Flashes GREEN in operation mode

    Temperate range-20°C  to +30°C  (E650C-R for moisture measurement)
    -20°C  to +30°C (E650C-G for moisture measurement)
    -30°C  to +40°C (GM-TA-AS with SM-TF130-DI module)
    -40°C  to +90°C (NTC-Sensor-10M with SM-TF130-DI module)
    Snow sensing thresholdsmax. range 0°C to +5°C
    min. range -30°C  to -5°C 
    OFF
    Sensor alarmSensor open circuit
    Sensor closed circuit
    Parameters

    Each parameter input and event logged, in non-volatile memory storage
    Communication
    Communication portRS-485
    Type2-wire RS-485
    CableOne shielded twisted pair (not included)
    Lengthup to 1,200 m
    Quantityup to 247 devices per port
    Data rate2400, 4800, 9600, 19200 baud
    ParityNone, even, odd
    Stop bits1, 2
    ProtocolModbus RTU
    Enclosure
    MaterialPolyphenylene Ether (PPE)
    Ingress protectionIP 20
    Mounting optionIn panel: mountable DIN rail 35 mm
    Storage temperature-20°C to +50°C 
    Flammability classD category DIN EN 60730 / VDE 0631-1
    Sensor: E650C-R (roof and gutter de-icing) 
    TypeNTC
    Tip dimensions⌀ 12 mm; length  (without support rings)
    L 105 mm, M6 thread (incl. plastic nut and plain washer)
    Cable connectionAxial
    Cable6 m  4 x 0.5 mm² cable; extendable (refer to Elexant E650C-Modbus installation manual)
    Temperature range-30°C to +80°C

    -20°C  to 30°C (for moisture measurement)
    * Not included in Elexant-E650C-Modbus
    Sensor: E650C-G (surface snow melting)
    TypeNTC
    Tip dimensions⌀ 68 mm; length 31 mm (without E650C-G-Housing)
    ⌀ 68 mm; length 31 mm (with E650C-G-Housing)
    Cable length20 m 4 x 0.5 mm² cable: extendable (refer to Elexant E650C-Modbus installation manual)
    Temperature range-30°C to +75°C
    -20°C  to +30°C (for moisture measurement)
    * Not included in Elexant-E650C-Modbus
    Sensor: GM-TA-AS (requires SM-TF130-DI module)
    TypeNTC 2 KOhm / 25°C  2-wire
    Enclosure materialPolycarbonate
    Enclosure dimensionsWidth: 50mm, Depth: 26mm, Length: 52mm
    Cable lengthSensor in a box ( no cable attached)
    Exposure temperature range-30°C  to +40°C
    Accuracy+/- 1 K
    * Not included in Elexant-E650C-Modbus
    Sensor: NTC-Sesnsor-10M (requires SM-TF130-DI module)
    TypeNTC 2 KOhm / 25°C  2-wire
    Tip dimensions⌀ 5 mm; length 20 mm
    Cable length10 m
    Temperature range-30°C  to +90°C
    Accuracy+/- 1 K
    * Not included in Elexant-E650C-Modbus
  • APPROVALS
    APPROVALS
    CE, ROHS, WEEE
    Complies to EMC EN 61000-6-3; EN 61000-6-2


  • DIMENSIONS
    DIMENSIONS AND WEIGHT
    Width158 mm
    Height110 mm (excluding glands)
    Depth65 mm
    Weight0.55 kg


  • DOWNLOAD DOCUMENTS