RAYCHEM EMDR-10 controller for snow and ice melting systems - nVent

nVent Raychem EMDR-10 control unit for snow and ice melting on roof and in gutters

RAYCHEM EMDR-10 controller for snow and ice melting systems - nVent


$0.00
$755.34
/ ea
Earn0
reward points

Lead time: 3 to 5 days


Product details

nVent RAYCHEM EMDR-10 electronic controller provides control of snow and ice melting RAYCHEM heating cables for roofs and gutters. The controller energises the heating circuits when the ambient temperature falls below a set point and moisture is detected.  The EMDR-10 saves energy using energy mode based on proportional ambient sensing control (PASC).

Features & Benefits

  • Precise control: Ambient and moisture sensing 
  • Efficiency: PASC based energy saving mode
  • Ease of use: Easy set up and programming
  • Adjustable range: -3°C to +6°C (ambient sensing) and 1  to 10 (moisture sensitivity)
  • Display: LEDs indicate operating conditions
  • Voltage: 230 VAC, ±10%, 50/60 Hz
  • Reliable: nVent RAYCHEM 6 six year available


  • TECHNICAL DETAILS
    SPECIFICATIONS
    Applicationsnow and ice melting on roofs and in gutters

    for nVent RAYCHEM FroStop Black and IceStop GM-2X, GM-2XT self-regulating heating cables
    Area of UseOrdinary area
    AssemblyDIN rail
    Exposure temperature range0°C to +50°C
    Electrical
    Supply voltage230 VAC, ±10%, 50/60 Hz
    Power consumption4 VA max
    Main relay (heating) Imax 10(4) A, 230 VAC, SPST, volt free
    Alarm relay Imax 2(1) A, 230 VAC, SPDT, volt free
    Switching accuracy± 1.5 K
    Terminals2.5 mm² to 4 mm²
    Display and programming
    LED indication
    1. Power ON; GREEN
    2. Temperature set point: YELLOW
    3. Moisture detection: YELLOW
    4. Heating cable ON: RED
    Temperature set points-3°C  to 6°C
    Low temperature range -25°C to -5°C
    Moisture sensitivity range1 (max) to 10 (min)
    Post heating time60 minutes (only in temperature range < +1.5°C), energy saving selectable
    Energy saving modePosition I: OFF
    Position II:  30% saving temperature range > +1.5°C
    Position III: 30% PASC control
    Direction connection of self-regulating heating cables up to 40 m length using position I only.  A contactor is required to use energy efficiency settings  position II and III
    Enclosure
    MaterialNoryl
    Ingress protectionIP 20 / class II (requirements of class II only fulfilled after proper mounting)
    Mounting optionDIN rail
    Sensor - Moisture (HARD-45)
    TypePTC  3 wire
    Sensor500 mm x 12 mm flat cable
    Cable length4 m (standard); extendable up to 100 m using  3 x 1.5 mm² cable
    Supply voltage230 VAC ± 10%
    Exposure temperature range-30°C  to +80°C
    Sensor - Ambient (VIA-DU-A10)
    TypePTC
    Enclsoure dimensions52 mm wide
    50 mm high
    35 mm depth
    Ingress protectionIP 54
    Terminals1.5 mm² to 2.5 mm²
    Cable2 x 1.5 mm², max length 100 m (not included)
    Exposure temperature range-30°C  to +80°C
    FixingWall mountable
  • APPROVALS
    APPROVALS
    CE certified


  • DIMENSIONS
    DIMENSIONS AND WEIGHT
    Width106 mm
    Height90 mm
    Depth58 mm
    Weight0.35 kg