RAYCHEM HTV self-regulating trace heating cable. Temperature maintenance in hazardous and non hazardous areas

nVent RAYCHEM HTV self-regulating high power retention trace heating cable. Colour dark red

RAYCHEM HTV self-regulating trace heating cable. Temperature maintenance in hazardous and non hazardous areas


$0.00
$66.61
/ metre
Earn0
reward points

This product has a minimum order quantity of 10 metres


Lead time: 3 to 5 days


Product details

nVent RAYCHEM HTV self-regulating trace heating cables provide freeze protection and process temperature maintenance up to 205°C of pipes/vessels which may be subjected to steam cleaning requirements. They withstand intermittent exposure to 260°C and are hazardous area approved Zone 1 and Zone 2 (Gas, Zone 21 and Zone 22 (Dust). The fluoropolymer outer jacket (-CT) provides high chemical resistance against aggressive organics and corrosives

Features & Benefits

  • High power retention: 95% after 10 years at 205°C
  • Unparalleled safety: unconditional T2 temperature class, no overheating.
  • Simple to design: long circuit lengths to 293 m, fewer power connections and faster installation
  • Easy to install: cut to length,can be overlapped, meter markings
  • Reliable long life: maintenance free, 10 year product warranty available
  • TECHNICAL DETAILS
    SPECIFICATIONS
    Applicationfreeze protection and temperature maintenance
    Max. maintain temperature205°C  (power on/off)
    Max. exposure temperature205°C - continuous
    260°C - intermittent (max. cumulative 2000 hours)
    Temperature classificationT3: all (except 20HTV2)
    T2: 20HTV2
    Min. installation temperature-60°C
    Supply voltageHTV2 - 230 Vac
    Chemical resistance-CT fluoropolymer jacket - organic corrosives
    HTV heating cable minimum bend radius at installation temperature
    Installation temperatureMinimum bend radius
    ≤ -60°C25 mm
    ≤ -20°C
    20 mm
    ≤ -10°C
    15 mm
    ≤ 0°C
    15 mm
    ≤ 10°C
    13 mm
    HTV heating cable maximum power output at 10°C
    CablePower output at 10°C
    3HTV29 W/m
    5HTV216 W/m
    8HTV225 W/m
    10HTV232 W/m
    12HTV238 W/m
    15HTV248 W/m
    20HTV264 W/m
    HTV heating cable maximum circuit length (m).  Circuit breaker (C-Type characteristic)
    CB size AStart-up temp.3HTV5HTV8HTV10HTV12HTV15HTV20HTV
    16-20°C1681269279675340
    +10°C 19714610690786146
    25-20°C
    2621971431231058263
    +10°C
    2932241651401219572
    32-20°C
    29322417315213410581
    +10°C
    29322417315213811992
    40-20°C
    29322417315213811988
    +10°C
    29322417315213811999
    * IMPORTANT* The above numbers are for circuit length estimation only. For more detailed information please request nVent RAYCHEM TraceCalc software design. nVent requires the use of a 30 mA residual current device to provide maximum safety and protection from fire. Where design results in higher leakage current, the preferred trip level for adjustable devices is 30 mA above any inherent capacitive leakage characteristic of the heater as specified by the trace heater supplier or alternatively, the next common available trip level for non adjustable devices, with a maximum of 300 mA. All safety aspects need to be proven
  • APPROVALS
    APPROVALS
    ATEX: SGS20ATEX0051X
    UKEX: BAS21UKEX0500X
    Ex II 2 GD Ex 60079-30-1 eb IIC 226°C(T2) Gb or Ex 60079-30-1 eb mb IIC 226°C(T2) Gb
    Ex II 2 GD EX 60079-30-1 tb IIIC T226°C Db or Ex 60079-30-1 mb tb IIIC T226°C Db

    Tmin -60°C

    IECEX: IEC Ex BAS 20.0014X
    Ex 60079-30-1 eb IIC T* Gb or Ex 60079-30-1 eb mb IIC T* Gb
    Ex 60079-30-1 tb IIIC T**°C Db or Ex 60079-30-1 mb tb IIIC T**°C Db
    Tmin -60°C

    EAC Ex: Approval for CIS region pending
    CCC: Approval for China pending


  • DIMENSIONS
    DIMENSIONS AND WEIGHT
    Thickness6.9 mm
    Width13.5 mm
    Weight0.17 kg/m
  • DOWNLOAD DOCUMENTS