Product details
HWAT cable: nVent RAYCHEM HWAT-L heating cable is designed to maintain hot water at a desired temperature within the buildings distribution system. Ideal for use within family homes and single flats HWAT-L can eliminate the need for recirculation within the hot water system or help optimise its performance if used in a hybrid approach.
HWAT Features & Benefits
- Instant hot water: improved delivery of hot water compared to recirculation systems
- Efficient: energy saving, reduced water use
- Simple to design: self-regulating flexible cable, cut to length
- Low installed cost: no need for return pipes, recirculation pumps, balancing valves or complex commissioning
- Control: maintain a specific water temperature, no return of cool water to the heater
- Precise control: advanced control and monitoring to maximum energy savings
- Reliable: 10 year warranty
- TECHNICAL DETAILS
SPECIFICATIONS Application Hot water temperature maintenance Min.nominal power output 7 W/m at 45°C Maximum circuit length 100 m Circuit beaker type /size Type C / max. 20 A Suitable for pipe material Copper: ✓
Threaded metal: ✓
Stainless steel: ✓
Composite metals: ✓
Plastics: ✓ - use with aluminium tape ATE-180Maximum exposure temperature 65°C - continuous Maximum exposure temperature 85°C - intermittent (power on) Braid Tinned copper Braid coverage 80 % Aluminium foil layer Yes ✓ Inner/outer jacket material Modified polyolefin Outer jacket colour Yellow Minimum bend radius 10 mm Supply voltage 230 VAC Chemical resistance Mild inorganic solutions HWAT cable
(230 VAC)Maximum circuit length (m). Based on start up temperature +12°C 10 13 16 20 HWAT-L 80 110 140 180 HWAT-M 50 65 80 100 HWAT-R 50 65 80 100 *** IMPORTANT *** 30 mA residual current device (RCD) and a circuit breaker (C-type characteristic) required for maximum safety and fire protection. - APPROVALS
APPROVALS Tested and approved IEC62395 and IEEE 515.1
BS, ÖVE, VDE, SEV, CSTB, SVGW, DVGW, CE - DIMENSIONS
DIMENSIONS AND WEIGHT Thickness 6.8 mm Width 13.8 mm Weight 0.12 kg/m Conductors 2 x 1.5 mm² nickel plated copper