Product details

chemelex® Raychem JBU-100 junction box. Electrostatic charge resistant glass filled engineered polymer enclosure, forms part of the modular components system and can be either pipe or wall mounted. The JBU-100 is approved for use in hazardous areas with chemelex® Raychem BTV, HTV, KTV, QTVR self-regulating heating cables, and chemelex® Raychem VPL power limiting heating cables.  

Features & Benefits

  • Versatile: pipe or wall mounted
  • Simple to design: up to 480 VAC, 53 A
  • Easy to install:spring type terminals; fast installation 
  • Reliable long life: maintenance free, 10 year product warranty available
  • TECHNICAL DETAILS
    SPECIFICATIONS
    Approvedchemelex® Raychem heating cables: BTV, HTV, KTV, QTRV & XTV self-regulating; VPL power limiting
    Rated voltage480 VAC
    Max. current rating(1)53 A
    LED (-L versions)colour: Green v
    voltage: 100 - 254 VAC
    power consumption: < 1 W
    Temperature rangeJBU-100-E & JBU-100-EP : -55°C to +56°C(2)
    JBU-100-L-E: & JBU-100-L-EP:  -40°C to +40°C
    Min. installation temperature-55°C
    Terminals6 x 10mm² spring type
    Entries4 x M25
    Enclosure materialElectrostatic charge resistant glass filled polymer: Colour BLACK
    Enclosure lid screwsstainless steel
    Enclosure lid gasketsilicone rubber
    Earth continuity plate (-EP versions)steel, zinc plated and blue chromated
    Temperature classificationIP66
    (1) For pipe temperatures > 150°C and < 260°C and, heating cables HTV, KTV, XTV the maximum operating current shall be reduced to 20 A
    (2) Extra conditions of safe use apply for ambient temperatures >+40°C. Temperature resistant power cable and metal glands must be used. 
    JBU-100 junction box kit contents
    ContentJBU-100-E
    JBU-100-EP

    JBU-100-EP
    JBU-100-L-EP
    Junction box with terminals11
    light module (for -L only)11
    M25 gland (cable ⌀8-15mm)1N/A
    M25 stopping plugs22
    * IMPORTANT* The above numbers are for circuit length estimation only. For more detailed information please request chemelex® Raychem TraceCalc software design. chemelex® requires the use of a 30 mA residual current device to provide maximum safety and protection from fire. Where design results in higher leakage current, the preferred trip level for adjustable devices is 30 mA above any inherent capacitive leakage characteristic of the heater as specified by the trace heater supplier or alternatively, the next common available trip level for non adjustable devices, with a maximum of 300 mA. All safety aspects need to be proven
  • APPROVALS
    APPROVALS
    ATEX: PTB20ATEX1008U
    Ex II 2 G Ex eb mb IIC Gb
    Ex II 2 D Ex tb mb IIIC Db

    IECEX: IEC PTB 20.0014X
    Ex eb mb IIC Gb
    Ex tb mb IIIC Db

    DNV: TAE0000TU and TAE00000TV
    The JBU-100 approved by DNV for use on ships and mobile offshore units

    EAC Ex: RU C-BE.MЮ62.B00054/18 
    Ex e IIC Gb U or Ex e mb IIC Gb U
    Ex tb IIIC Db U or Ex tb mb IIIC Db U
    Ta -55°C...+56°C  IP66
    Ta -55°C...+40°C IP66 (-L versions only)
    ООО "ТexИмпорт
    CCC - JBU-100-E (EP)
    Ex e IIC Gb
    Ex tD A21 IP66

    CCC - JBU-100-L-E (EP)
    Ex e mb IIC Gb
    Ex tD A21 mbD 21 IP66


  • DIMENSIONS
    DIMENSIONS AND WEIGHT
    JBU-100 versions

    -E-EP-L-E_L-EP
    Mounting holes (mm)6666
    Width (mm)
    160
    160160160
    Height (mm)
    160
    160160160
    Weight (kg)
    1.7
    1.82.12.2
  • DOWNLOAD DOCUMENTS