RAYCHEM KTV self-regulating trace heating cable. Temperature maintenance in hazardous and non hazardous areas

nVent RAYCHEM KTV self-regulating heating cable. Colour dark red

RAYCHEM KTV self-regulating trace heating cable. Temperature maintenance in hazardous and non hazardous areas


$0.00
$108.17
/ metre
Earn0
reward points

This product has a minimum order quantity of 10 metres


Lead time: 3 to 5 days


Product details

nVent RAYCHEM KTV self-regulating trace heating cables provide process temperature maintenance up to 150°C of pipes/vessels which may be subjected to steam cleaning requirements. They withstand intermittent exposure to 250°C and are hazardous area approved Zone 1 and Zone 2 (Gas, Zone 21 and Zone 22 (Dust). The fluoropolymer outer jacket (-CT) provides high chemical resistance against aggressive organics and corrosives

Features & Benefits

  • Unparalleled safety: unconditional T2 temperature class, no overheating.
  • Simple to design: long circuit lengths to 230 m, fewer power connections and faster installation
  • Easy to install: cut to length,can be overlapped, meter markings
  • Reliable long life: maintenance free, 10 year product warranty available
  • TECHNICAL DETAILS
    SPECIFICATIONS
    Applicationtemperature maintenance
    Max. maintain temperature150°C  (power on/off)
    Max. exposure temperature150°C - continuous
    250°C - intermittent (max. cumulative 1000 hours)
    Temperature classificationT2
    Min. installation temperature-60°C
    Supply voltageKTV2 - 230 Vac
    Chemical resistance-CT fluoropolymer jacket - organic corrosives
    KTV heating cable minimum bend radius at installation temperature
    Installation temperatureMinimum bend radius
    ≤ -60°C26 mm
    ≤ -20°C
    20 mm
    ≤ -10°C
    15 mm
    ≤ 0°C
    15 mm
    ≤ 10°C
    12 mm
    KTV heating cable maximum power output at 10°C
    CablePower output
    5KTV216 W/m
    8KTV225 W/m
    15KTV247 W/m
    20KTV266 W/m
    KTV heating cable maximum circuit length (m).  Circuit breaker (C-Type characteristic)
    CB size AStart-up temp.5KTV8KTV15KTV20KTV
    16-20°C130956040

    +10°C 1451056545
    25-20°C
    2051509065

    +10°C
    23016510075
    32-20°C
    23018011575

    +10°C
    23018013085
    40-20°C
    230180130105

    +10°C
    230180130110
    * IMPORTANT* The above numbers are for circuit length estimation only. For more detailed information please request nVent RAYCHEM TraceCalc software design. nVent requires the use of a 30 mA residual current device to provide maximum safety and protection from fire. Where design results in higher leakage current, the preferred trip level for adjustable devices is 30 mA above any inherent capacitive leakage characteristic of the heater as specified by the trace heater supplier or alternatively, the next common available trip level for non adjustable devices, with a maximum of 300 mA. All safety aspects need to be proven
  • APPROVALS
    APPROVALS
    ATEX: SGS20ATEX0051X
    UKEX: BAS21UKEX0500X
    Ex II 2 GD Ex 60079-30-1 eb IIC 226°C(T2) Gb or Ex 60079-30-1 eb mb IIC 226°C(T2) Gb
    Ex II 2 GD EX 60079-30-1 tb IIIC T226°C Db or Ex 60079-30-1 mb tb IIIC T226°C Db

    Tmin -60°C

    IECEX: IEC Ex BAS 20.0014X
    Ex 60079-30-1 eb IIC T* Gb or Ex 60079-30-1 eb mb IIC T* Db
    Ex 60079-30-1 tb IIIC T**°C Db or Ex 60079-30-1 mb tb IIIC T**°C Db
    Tmin -60°C

    DNV: TAE0000TV
    The KTV heating cables are approved by DNV for use on ships and mobile offshore units

    EAC Ex: RU C-BE.ИM43.B.01712 
    1Ex e IIC 226 Gb X or 1Ex e mb II C T* Gb X
    Ex tb IIIC T226°C Db X or Ex tb mb T*°C Db X 
    Ta -60°C...+56°C  IP66


  • DIMENSIONS
    DIMENSIONS AND WEIGHT
    All KTV cables
    Thickness (mm)
    7.6
    Width (mm)
    13.5
    Weight (kg/m)
    0.25

  • DOWNLOAD DOCUMENTS