Product details
Trace heating control panel for gutter freeze prevention. The chemelex® Raychem SBS-EV-10 control panel, combines with all GM-2X and GM-2XT self-regulating heating cables and Raychem components to provide a complete solution for gutter and drainpipe freeze protection applications.
Features & Benefits
- Switching: up to 12 trace heating circuits
- Flexible control: Moisture and ambient sensing
- Control: Raychem EMDR-10 Smart control device
- Simple to design: direct connection of heating cables, no additional junction boxes needed
- Safety: integrated circuit over current and RCD protection
- LED indication: LEDs provide circuit ON (GREEN) status and common FAULT (RED)
- Robust: IP65 sheet steel wall mounted enclosure
- Design: optimal components selected for freeze protection system
- TECHNICAL DETAILS
SPECIFICATIONS Application Gutter and drainpipe freeze prevention for chemelex® Raychem GM-2X and GM-2XT Area of Use Ordinary area, indoors Exposure temperature range 10°C to +35°C ambient Electrical Panel Option 3 Way 6 Way 9 Way 12 Way Maximum number of heating circuits 3 6 9 12 Main Incomer A 32 63 63 100 Quantity of contactors 1 2 3 4 Supply voltage 400 VAC 3 phase, N and PE Heating circuit supply voltage 230 VAC 50/60 Hz Terminals Heating cable: 3 x 10 mm²
Sensor: 2 x 1.5 mm²Circuit breaker 1 x 20 A (C-type characteristic), per heating circuit RCD 30 mA Alarm 1 potential free contact in panel; 1 alarm LED in the door EMDR-10 Control and Monitoring Screen type Touch screen, size 4.3" LED indication (GREEN) - power ON
- temperature set point YELLOW
- moisture sensitivity YELLOW
- heating circuit on RED
Temperature set points -3°C to +6°C: factory default +2°C Lower temperature limit range -25°C to -5°C: factory default -15°C Operating differential ± 0.5 K Measuring accuracy ± 1.5 K Moisture sensitivity range 1 (max.) to 10 (min.): factory default 5 Post heating time 60 minutes energy saving, selectable: (only in temperature range < +1.5°C) Enclosure Material Sheet steel, textured paint, RAL 7035, light gray Ingress protection IP65 Mounting option Wall mounted Entries Bottom face (gland plate) Sensor - Moisture Type PTC 3 wire Sensor 650 mm flat cable Cable length 4 m (standard); extendable up to 100 m using 3 x 1.5 mm² cable Supply voltage 230 VAC ±10 % Ambient temperature range -30°C to +65°C continuous Sensor - Ambient Type PTC Enclosure dimensions 52 mm wide
50 mm high
35 mm depthIngress protection IP54 Terminals 1.5 to 2.5 mm² Cable 2 x 1.5 mm², max. length 100 m (not included) Fixing Wall mountable - APPROVALS
APPROVALS CE IEC 61439 - DIMENSIONS
DIMENSIONS AND WEIGHT Number of heating circuits 3 6 9 12 Width mm 400 600 600 600 Height mm 600 600 600 800 Depth mm 210 210 210 210 Weight kg `32 45 45 90 - DOWNLOAD DOCUMENTS