RAYCHEM XPI-S polymer insulated series resistance heat trace heating cable, 7 joule. Hazardous and non hazardous areas - nVent

nVent RAYCHEM XPI-S polymer insulated series resistance trace heating cable: Freeze protection and temperature maintenance for pipes, vessels and equipment.  XPI-S cables are approved for use in hazardous and non hazardous areas

RAYCHEM XPI-S polymer insulated series resistance heat trace heating cable, 7 joule. Hazardous and non hazardous areas - nVent


$0.00
$18.07
/ metre
Earn0
reward points

This product has a minimum order quantity of 10 metres


Lead time: up to 8 weeks


Product details

nVent RAYCHEM XPI-S polymer insulated series resistance trace heating cables provide freeze protection process temperature maintenance of pipes,vessels and other equipment which may be subjected to steam cleaning requirements. They withstand intermittent exposure to 300°C and are hazardous area approved Zone 1 and Zone 2 (Gas, Zone 21 and Zone 22 (Dust). The PTFE outer jacket provides high chemical resistance against aggressive organics and corrosives

Features & Benefits

  • High output: high power output at elevated temperatures
  • Reduced equipment cost: lower power to temperature start up power; reduced CB sizing
  • Simple to design: long circuit lengths, fewer power connections and faster installation
  • Easy to install: flexible cable, easy termination components
  • Reliable long life: maintenance free, 10 year product warranty available
  • TECHNICAL DETAILS
    SPECIFICATIONS
    Applicationfreeze protection and temperature maintenance
    Max. exposure temperature **260°C - continuous
    300°C - intermittent 
    Maximum power output35 W.m
    Min. installation temperature-70°C
    Supply voltageUp to 450/750 V a.c.  (UO/U)
    Temperature classificationT2-T6
    Minimum cable spacing20 mm
    Impact resistance7 Joule (as per EN 60079-30-1)
    Chemical resistancePTFE outer jacket - organic corrosives
    XPI-S heating cable minimum bend radius at installation temperature -70°C
    Cable diameterMinimum bend radius
    < 6 mm
    2.5 x cable diameter
    ≥ 6 mm
    6 x cable diameter
    XPI-S heating cable maximum power output  (W/m)
    Maintain temperature (°C)Good surface contactPoor surface contact
    ≤ +103025
    +11 to 302520
    +31 to 502118
    +51 to 751815
    +76 to 1001512
    +101 to 1251210
    +126 to 150108
    +151 to 20085
  • APPROVALS
    APPROVALS
    ATEX: PTB 08 ATEX 1102X
    Ex II 2 G/D Ex e II T2...T6
    Ex tD A21 IP65 T290...T80°C

    IECEX: PTB 08.0051X
    Ex II 2 G/D Ex e II T2...T6
    Ex tD A21 Ip65 T290...T80°C

    EAC Ex: RU C-BE.ИМ43.B01854 
    1Ex e IIC T6 (80°C)...T2(290°C) Gb X
    Ex tb IIIC T80°C...290°C Db X IP66
    Ta -70°C...+56°C 
    ООО "ТexИмпорт
    Made in Germany


  • DIMENSIONS
    XPI-S heating cable reference guide
    Cable referenceNominal resistance
    [Ω/km @ 20°C]
    Temp coefficient
    [ x10-3/K]
    Outer diameter
    [mm]
    Nominal weight
    [kg/km]
    XPI-S-0.80.84.311.9405
    XPI-S-1.11.14.310.1307
    XPI-S-1.81.84.38.6209
    XPI-S-2.92.94.36.9149
    XPI-S-4.44.44.36.1116
    XPI-S-77.04.35.588
    XPI-S-1010.04.35.484
    XPI-S-11.711.74.35.276
    XPI-S-1515.04.35.171
    XPI-S-17.817.84.34.968
    XPI-S-2525.03.04.972
    XPI-S-31.531.51.35.382
    XPI-S-50501.34.972
    XPI-S-6565134.866
    XPI-S-80800.75.175
    XPI-S-1001000.45.279
    XPI-S-1501500.44.978
    XPI-S-1801800.334.771
    XPI-S-2002000.44.872
    XPI-S-3203200.184.976
    XPI-S-3803800.184.873
    XPI-S-4804800.184.770
    XPI-S-6006000.184.567
    XPI-S-7007000.184.565
    XPI-S-8108100.044.669
    XPI-S-100010000.044.567
    XPI-S-144014400.044.469
    XPI-S-175017500.044.367
    XPI-S-200020000.354.674
    XPI-S-300030000.354.469
    XPI-S-400040000.354.265
    XPI-S-440044000.14.366
    XPI-S-516051600.14.366
    XPI-S-560056000.14.263
    XPI-S-700070000.14.261
    XPI-S-800080000.14.160