Product details
nVent RAYCHEM XPI-S polymer insulated series resistance trace heating cables provide freeze protection process temperature maintenance of pipes,vessels and other equipment which may be subjected to steam cleaning requirements. They withstand intermittent exposure to 300°C and are hazardous area approved Zone 1 and Zone 2 (Gas, Zone 21 and Zone 22 (Dust). The PTFE outer jacket provides high chemical resistance against aggressive organics and corrosives
Features & Benefits
- High output: high power output at elevated temperatures
- Reduced equipment cost: lower power to temperature start up power; reduced CB sizing
- Simple to design: long circuit lengths, fewer power connections and faster installation
- Easy to install: flexible cable, easy termination components
- Reliable long life: maintenance free, 10 year product warranty available
- TECHNICAL DETAILS
SPECIFICATIONS Application freeze protection and temperature maintenance Max. exposure temperature ** 260°C - continuous
300°C - intermittentMaximum power output 35 W.m Min. installation temperature -70°C Supply voltage Up to 450/750 V a.c. (UO/U) Temperature classification T2-T6 Minimum cable spacing 20 mm Impact resistance 7 Joule (as per EN 60079-30-1) Chemical resistance PTFE outer jacket - organic corrosives XPI-S heating cable minimum bend radius at installation temperature -70°CCable diameter Minimum bend radius < 6 mm 2.5 x cable diameter ≥ 6 mm 6 x cable diameter XPI-S heating cable maximum power output (W/m) Maintain temperature (°C) Good surface contact Poor surface contact ≤ +10 30 25 +11 to 30 25 20 +31 to 50 21 18 +51 to 75 18 15 +76 to 100 15 12 +101 to 125 12 10 +126 to 150 10 8 +151 to 200 8 5 - APPROVALS
APPROVALS ATEX: PTB 08 ATEX 1102X
Ex II 2 G/D Ex e II T2...T6
Ex tD A21 IP65 T290...T80°CIECEX: PTB 08.0051X
Ex II 2 G/D Ex e II T2...T6
Ex tD A21 Ip65 T290...T80°CEAC Ex: RU C-BE.ИМ43.B01854
1Ex e IIC T6 (80°C)...T2(290°C) Gb X
Ex tb IIIC T80°C...290°C Db X IP66
Ta -70°C...+56°C
ООО "ТexИмпорт
Made in Germany - DIMENSIONS
XPI-S heating cable reference guide Cable reference Nominal resistance
[Ω/km @ 20°C]Temp coefficient
[ x10-3/K]Outer diameter
[mm]Nominal weight
[kg/km]XPI-S-0.8 0.8 4.3 11.9 405 XPI-S-1.1 1.1 4.3 10.1 307 XPI-S-1.8 1.8 4.3 8.6 209 XPI-S-2.9 2.9 4.3 6.9 149 XPI-S-4.4 4.4 4.3 6.1 116 XPI-S-7 7.0 4.3 5.5 88 XPI-S-10 10.0 4.3 5.4 84 XPI-S-11.7 11.7 4.3 5.2 76 XPI-S-15 15.0 4.3 5.1 71 XPI-S-17.8 17.8 4.3 4.9 68 XPI-S-25 25.0 3.0 4.9 72 XPI-S-31.5 31.5 1.3 5.3 82 XPI-S-50 50 1.3 4.9 72 XPI-S-65 65 13 4.8 66 XPI-S-80 80 0.7 5.1 75 XPI-S-100 100 0.4 5.2 79 XPI-S-150 150 0.4 4.9 78 XPI-S-180 180 0.33 4.7 71 XPI-S-200 200 0.4 4.8 72 XPI-S-320 320 0.18 4.9 76 XPI-S-380 380 0.18 4.8 73 XPI-S-480 480 0.18 4.7 70 XPI-S-600 600 0.18 4.5 67 XPI-S-700 700 0.18 4.5 65 XPI-S-810 810 0.04 4.6 69 XPI-S-1000 1000 0.04 4.5 67 XPI-S-1440 1440 0.04 4.4 69 XPI-S-1750 1750 0.04 4.3 67 XPI-S-2000 2000 0.35 4.6 74 XPI-S-3000 3000 0.35 4.4 69 XPI-S-4000 4000 0.35 4.2 65 XPI-S-4400 4400 0.1 4.3 66 XPI-S-5160 5160 0.1 4.3 66 XPI-S-5600 5600 0.1 4.2 63 XPI-S-7000 7000 0.1 4.2 61 XPI-S-8000 8000 0.1 4.1 60