RAYCHEM XTV self-regulating trace heating cable. This product is now superseded - See RAYCHEM XTVR self-regulating trace heating cable. - nVent
RAYCHEM XTV self-regulating trace heating cable. This product is now superseded - See RAYCHEM XTVR self-regulating trace heating cable. - nVent
Product details
nVent RAYCHEM XTV self-regulating trace heating cables provide process temperature maintenance up to 121°C of pipes/vessels which may be subjected to steam cleaning requirements. They withstand intermittent exposure to 250°C and are hazardous area approved Zone 1 and Zone 2 (Gas, Zone 21 and Zone 22 (Dust). The fluoropolymer outer jacket (-CT) provides high chemical resistance against aggressive organics and corrosives
Features & Benefits
- Unparalleled safety: unconditional T2 temperature class, no overheating.
- Simple to design: long circuit lengths to 245 m, fewer power connections and faster installation
- Easy to install: cut to length,can be overlapped, meter markings
- Reliable long life: maintenance free, 10 year product warranty available
- TECHNICAL DETAILS
SPECIFICATIONS Application Freeze protection, temperature maintenance Max. maintain temperature 121°C (power on/off) Max. exposure temperature 121°C - continuous
250°C - intermittent (max. cumulative 1000 hours)Temperature classification T3: all (except 20XTV2)
T2: 20XTV2Min. installation temperature -60°C Supply voltage XTV2 - 230 Vac Chemical resistance -CT fluoropolymer jacket - organic corrosives XTV heating cable minimum bend radius at installation temperatureInstallation temperature Minimum bend radius ≤ -60°C 51 mm ≤ -20°C 35 mm ≤ -10°C 25 mm ≤ 0°C 25 mm ≤ 10°C 20 mm ≥ 20°C 13 mm XTV heating cable maximum power output at 10°C Cable Power output at 10°C 4XTV2 12 W/m 8XTV2 25 W/m 12XTV2 38 W/m 15XTV2 47 W/m 20XTV2 63 W/m XTV heating cable maximum circuit length (m). Circuit breaker (C-Type characteristic) CB size A Start-up temp. 4XTV 8XTV 12XTV 15XTV 20XTV 16 -20°C 145 90 65 55 40 +10°C 170 105 75 60 45 25 -20°C 225 145 105 85 65 +10°C 245 165 120 95 70 32 -20°C 245 175 135 105 80 +10°C 245 175 140 125 90 40 -20°C 245 175 140 135 110 +10°C 245 175 140 135 110 * IMPORTANT* The above numbers are for circuit length estimation only. For more detailed information please request nVent RAYCHEM TraceCalc software design. nVent requires the use of a 30 mA residual current device to provide maximum safety and protection from fire. Where design results in higher leakage current, the preferred trip level for adjustable devices is 30 mA above any inherent capacitive leakage characteristic of the heater as specified by the trace heater supplier or alternatively, the next common available trip level for non adjustable devices, with a maximum of 300 mA. All safety aspects need to be proven - APPROVALS
APPROVALS ATEX: SGS20ATEX0049X
UKEX: BAS21UKEX0499X
Ex II 2 GD Ex 60079-30-1 eb IIC T* Gb or Ex 60079-30-1 eb mb IIC T* Gb
Ex II 2 GD EX 60079-30-1 tb IIIC T**°C Db or Ex 60079-30-1 mb tb IIIC T**°C Db
Tmin -60°CIECEX: IEC Ex BAS 20.0012X
Ex 60079-30-1 eb IIC T* Gb or Ex 60079-30-1 eb mb IIC T* Gb
Ex 60079-30-1 tb IIIC T**°C Db or Ex 60079-30-1 mb tb IIIC T**°C Db
Tmin -60°CDNV: TAE0000TV
The XTV heating cables are approved by DNV for use on ships and mobile offshore unitsEAC Ex: RU C-BE.ИM43.B.01712
1Ex e IIC T* Gb X 1Ex e mb II C T* Gb X
Ex tb IIIC T*°C Db X Ex tb mb T*°C Db X
Ta -60°C...+56°C IP66 - DIMENSIONS
DIMENSIONS AND WEIGHT All XTV cables Thickness (mm) 7.2 Width (mm) 11.7 Weight (kg/m) 0.17 - DOWNLOAD DOCUMENTS