RAYCHEM XL-Trace 26XL2-ZH contractor pack. 26 watt per metre frost protection heating cable. - nVent

Raychem XL-Trace 26XL2-ZH contractor pack. 26 watt per metre frost protection heating cable. Colour blue

RAYCHEM XL-Trace 26XL2-ZH contractor pack. 26 watt per metre frost protection heating cable. - nVent


$0.00
$1,178.62
/ pk
Earn0
reward points


Lead time: 3 to 5 days


Product details

nVent RAYCHEM XL-Trace 26XL2 contractor pack comprises a fixed length of 26XL2-ZH heating cable supplied in an easy to use and carry spool box. The spool allows the installer to feed out the required length easily, reducing installation time and effort.  nVent RAYCHEM XL-Trace range ensures frost protection for pipes exposed to sub-zero temperatures. This self-regulating heating cable range, combined with pipe insulation prevent water pipes, fire mains and sprinklers from freezing. Developed for use within commercial and residential buildings. XL-Trace cables are designed for use with a RayClic fast connection device.

XL-Trace Features & Benefits

  • Unparalleled safety: low smoke zero halogen: up to 90% less smoke emissions, improved self-extinguishing properties
  • Simple to design: long circuit lengths to 142 m, for fewer power connections and faster installation
  • Easy to install: highly flexible cable, cut to length, fast RayClic cold connection system
  • Energy efficient and safe: self-regulating cable, advanced energy saving controls, major savings when used with proportional ambient sensing controller (PASC), no cable overheating possible
  • Reliable long life: UV resistant, colorfast, maintenance free, 10 year product warranty available


  • TECHNICAL DETAILS
    SPECIFICATIONS
    ApplicationPipe freeze protection
    Min.nominal power output 26 W/m at 5°C
    Suitable for pipe materialCopper: 
    Threaded metal: 

    Stainless steel: 

    Composite metals: 

    Plastics: 
      - use with aluminium tape ATE-180
    Maximum exposure temperature 
    65°C - continuous (power on/off)
    Maximum exposure temperature
    85°C - intermittent (power on/off)
    Max. cumulative exposure 800 hours
    Minimum installation temperature-40°C
    Minimum bend radius10 mm
    Supply voltage230 Vac 
    Chemical resistanceMild inorganic solutions
    Switch-on temp.Maximum circuit length (m). Circuit breaker size (C-type characteristic)
    610131620
    -20°C2847627695
    -10°C33557188110
    -5°C36608696112
    0°C406686105132
    5°C447394116142
    Quick cable selection guide for pipe freeze protection at -20°C
    Insulation thickness

    Maximum pipe diameter (mm) for XL-Trace cable
    10XL215XL226XL231XL2
    ≥10 mm
    ≤15
    ≤22
    ≤67
    ≤200
    ≥15 mm ≤28≤54
    ≤108
    ≤200
    ≥20 mm≤42≤67
    ≤108
    ≤200
    ≥25 mm≤54≤76
    ≤150
    ≤200
    ≥30 mm
    ≤67
    ≤108
    ≤200
    ≤200
    ≥40 mm
    ≤76≤125
    ≤200
    ≤200
    ≥50 mm
    ≤108
    ≤125≤200
    ≤200
    *** IMPORTANT *** For insulation types containing solvents and/or bitumen coating, use 31XL2-ZH
    Quick cable length estimation guide
    Total installed pipe length(m)
    + for each RayClic CE-020.3 m 
    + for each RayClic PS-020.6 m 
    + for each RayClic PT-020.9 m
    + for each RayClic S-020.6 m 
    + for each RayClic T-020.9 m
    + for each RayClic X-021.2 m
    + pipe ≥2" NB, 60 mm dia. for each valve1 m
    + pipe ≥2" NB, 60 mm dia. for each uninsulated support1m
    = Total heating cable length(m)
    *** IMPORTANT ***
    The heating cable should be installed in a straight line on the pipe in accordance with nVent RAYCHEM installation instructions.

    Cable loops instead of RayClic T-02 T-connectors can be made on short "dead legs" not exceeding 3 metre
    s
  • APPROVALS
    APPROVALS
    IEC62395:2013CE, VDE, EAC, CSTB
    IEC60754-1Zero halogen insulation material
    IEC61034-2Low smoke emissions
    IEC60068-2-5 and IEC60068-2-9UV resistance


  • DIMENSIONS
    DIMENSIONS AND WEIGHT
    Thickness6.8 mm
    Width13.8 mm
    Weight0.135 kg/m
    Conductors1.3 mm² nickel plated copper
  • DOWNLOAD DOCUMENTS