Product details
nVent RAYCHEM XTVR self-regulating trace heating cables provide freeze protection and process temperature maintenance up to 150°C of pipes/vessels which require high power output and, or exposure to higher temperatures. The XTVR is the next generation of the XTV range, now with a new high power retention (HPR) heating core. XTVR cable can withstand intermittent exposure to 250°C (2000 cumulative hours) and are hazardous area approved Zone 1 and Zone 2 (Gas, Zone 21 and Zone 22 (Dust). The fluoropolymer outer jacket (-CT) provides high chemical resistance against aggressive organics and corrosives
Features & Benefits
Higher Temperature
| |
Superior Performance
| |
Legacy Proven Design
| |
More Power Variants
|
- TECHNICAL DETAILS
SPECIFICATIONS Application freeze protection and temperature maintenance Max. maintain temperature 150°C (power on/off) Max. exposure temperature 150°C - continuous
250°C - intermittent (max. cumulative 2000 hours)Temperature classification,/span. T3: all (except 20XTVR2-CT)
T2: 20XTVR2-CT
T6...T4: XTVR2-CT by using principles of either stabilized or controlled limited designMin. installation temperature -60°C Supply voltage 230 V.a.c. Chemical resistance fluoropolymer jacket - organic corrosives RAYCHEM XTVR heating cable minimum bend radius at installation temperatureInstallation temperature Minimum bend radius ≤ -60°C 51 mm ≤ -20°C 35 mm ≤ -10°C 25 mm ≤ 0°C 20 mm ≤ 10°C 12 mm RAYCHEM XTVR heating cable maximum power output at 10°C Cable Power output at 10°C 3XTVR2-CT 9 W/m 5XTVR2-CT 16 W/m 8XTVR2-CT 25 W/m 10XTVR2-CT 32 W/m 12XTVR2-CT 38 W/m 15XTVR2-CT 48 W/m 20XTVR2-CT 64 W/m RAYCHEM XTVR heating cable maximum circuit length (m). Circuit breaker (C-Type characteristic) CB size A Start-up temp. 3XTVR2 5XTVR2 8XTVR2 10XTVR2 12XTVR2 15XTVR2 20XTVR2 16 -20°C 165 123 112 76 66 49 39 +10°C 193 124 130 89 77 57 45 20 -20°C 206 154 140 95 82 62 49 +10°C 241 180 162 111 96 72 57 25 -20°C 258 192 143 119 103 77 61 +10°C 290 221 165 139 120 90 71 32 -20°C 290 221 173 151 131 99 78 +10°C 290 221 173 151 135 115 91 40 -20°C 290 221 173 151 135 120 88 +10°C 290 221 173 151 135 120 101 * IMPORTANT* The above numbers are for circuit length estimation only. For more detailed information please request nVent RAYCHEM TraceCalc software design. nVent requires the use of a 30 mA residual current device to provide maximum safety and protection from fire. Where design results in higher leakage current, the preferred trip level for adjustable devices is 30 mA above any inherent capacitive leakage characteristic of the heater as specified by the trace heater supplier or alternatively, the next common available trip level for non adjustable devices, with a maximum of 300 mA. All safety aspects need to be proven - APPROVALS
APPROVALS ATEX: SGS20ATEX0049X
UKEX: BAS21UKEX0499X
Ex II 2 G Ex 60079-30-1 eb IIC T* Gb or Ex 60079-30-1 eb mb IIC T* Gb
Ex II 2 D EX 60079-30-1 tb IIIC T** °C Db or Ex 60079-30-1 mb tb IIIC T** °C Db
Tmin -60°C (* ** see schedule)IECEX: IEC Ex BAS 20.0012X
Ex 60079-30-1 eb IIC T* Gb or Ex 60079-30-1 eb mb IIC T* Gb
Ex 60079-30-1 tb IIIC T**°C Db or Ex 60079-30-1 mb tb IIIC T**°C Db
Tmin -60°C (* ** see schedule)EAC Ex: Approval for CIS region pending CCC: Approval for China pending - DIMENSIONS
DIMENSIONS AND WEIGHT Thickness 7.2 mm Width 10.8 mm Weight 0.16 kg/m - DOWNLOAD DOCUMENTS